
Tipiak
The following provides a summary of the features and specifications for the eServer xSeries 360 server. Depending on the server model, some features and specifications might not apply. Microprocessor Intel Xeon processor MP (frequency varies with server model; each MP processor functions as two logical processors) Minimum: two Maximum: four Level 3 cache size varies with model 100MHz front side bus (FSB) Chipset IBM XA-32 chipset with integrated memory, I/O controller, and remote I/O controller. Memory DDR registered SDRAM DIMMs with ECC and Chipkill™ memory Minimum: 512MB Maximum: 8GB Slots Interleaved, 8 slots Drives standard Slim diskette: 1.44MB Slim CD-ROM: 24x-10x IDE Hard disk drives Slim line hot-swap drives (number of drives and drive capacity vary with model). Maximum: Three Active PCI expansion slots Two 100MHz/ 64-bit PCI-X Four 66MHz/ 64-bit PCI-X Hot-swap power supplies 370W (115-230V AC) Minimum: One or two power supplies are shipped with server, depending on model Maximum: Three Hot-swap cooling Six hot-swap fans Video S3 video controller Compatible with SVGA 4 8MB SDRAM video memory Size (3 U) Height: 134mm (5.28 inch) Depth: 720mm (28.35 inch) Width: 440mm (17.32 inch) Weight: 25kg (55 lb) to 31.7kg (70 lb) depending upon configuration Integrated functions Light Path Diagnostics Ultra160 SCSI controller One 10BASE-T/ 100BASE-TX Intel Ethernet controller Remote Supervisor Adapter (RSA) service processor ASM interconnect (peer-to-peer) port RXE Expansion port RXE management port Ethernet port Serial port Three universal serial bus ports Keyboard port Mouse port Video port Acoustical noise emissions Sound power, idling: 6.3 bel maximum Sound power, operating: 6.3 bel maximum Sound pressure, operating: 47 dBa maximum Environment Air temperature Server on: 10° to 35° Celsius (50° to 95° Fahrenheit). Altitude: 0 to 914m (3000 ft) Server on: 10° to 32° Celsius (50° to 89.6° Fahrenheit). Altitude: 914m (3000 ft) to 2133m (7000 ft) Server off: 10° to 43° Celsius (50° to 110° Fahrenheit). Maximum altitude: 2133m (7000 ft) Humidity Server on: 8 % t o 8 0% Server off: 8% to 80% Heat output Approximate heat output in British thermal units (Btu) per hour Minimum configuration: 1232 Btu (0.36 kilowatts) Maximum configuration: 3566 Btu (1.045 kilowatts) Electrical input Sine-wave input (50-60Hz) required Input voltage low range: Minimum: 100V AC Maximum: 127V AC Input voltage high range: Minimum: 200V AC Maximum: 240V AC Input kilovolt-amperes (kVA) approximately: Minimum: 0.08 kVA (ac power connected, server off) Minimum: 0.38 kVA (dc power on, server idle) Maximum: 1.1 kVA